Nebula IOS Acquisition System BAT-NEIOS-16V-V001
Product details:
BAT-NEIOS-16V-V001 is a new generation of multi-functional integrated data acquisition system. With internal high-speed data communication bus, the device can collect and control a variety of signals for monitoring the voltage and temperature of battery packs during the cycling test process. The monitored voltage and temperature value can help the technical personnel analyze the battery packs as well as act as the judgement and alarm during the test of working condition
About Nebula
Nebula is a global leader in advanced battery testing equipment, renowned for its precision, reliability, and cutting-edge technology. Our comprehensive product range supports a wide array of applications, including battery R&D, manufacturing automation, and energy storage systems. With a dedicated after-sales service team based in North America, we provide direct, localized support to ensure seamless operation and customer satisfaction. Nebula’s commitment to innovation and quality positions us at the forefront of the industry, empowering clients worldwide to achieve exceptional performance and sustainability goals.
NANOSSR is an authorized distributor of Nebula in the USA. The product figure is for reference only. The actual product may look different based on product configuration.
NANOSSR is a US-based leading supplier of battery research materials and equipment with thousands of customers worldwide.
Specifications:
Working voltage | 220VAC±10% , frequency of 60Hz |
Max. Power of single chassis | 125W |
Noise | Fanless design, zero noise |
IP Rating (Optional) | IP21 |
Device operating temperature | 0~50℃ |
Communication board interface | Ethernet, CANFD (CAN2.0 compatible), supports more than 2 chassis in parallel |
Number of slots per chassis | 10 slots |
Channel acquisition frequency | Voltage board≤200Hz |
Chassis cascade scalability | Supports up to 3 chassis in series |
Voltage acquisition card (Optional) | Measurement range: -5V-+10V@<7.5 mv; 0-+5V@<2.5mv, Number of channels per card: 16CH, Measurement accuracy: 0.05%FS, Operating temperature: 0-50℃ |
Thermocouple temperature acquisition card (Optional) | Measurement range: -40℃-+200℃, Number of channels per card: 16CH, Accuracy1: ±0.5℃(15-35℃), Operating temperature: 15-35℃, Accuracy 2: ±1℃(0℃-50℃) |
NTC temperature acquisition card (Optional) | Measurement range: -20℃-+120℃, Number of channels per card: 16CH, Accuracy: ±1℃ |
Digital IO card (Optional) | 8-channel DI+8-channelDO, DO for dry contact; DI for input judgement, low level when below 1.5V, Voltage≤60V |
PWM card (Optional) | Channel: 2CH, Frequency: 0-30KHz, Duty Ratio:(1KHz-2KHz)1-99%(2KHz-10KHz)10-90%, Accuracy: ±1us, Output voltage: 0-13V 5-13V can be set, Accuracy: ±200mV |
Monitoring card (Optional) | Support voltage upper and lower limit setting and monitoring, as well as dry contact control |
Handheld setup box (Optional) | Use with monitoring card to set upper and lower voltage limits |
Dimension (W*D*H) | 320mm*265.5mm*220mm |
Weight | Approximately 2.5KG (when fully loaded with circuit boards) |